Model: NL-ZXCG-2
The problem
The central sensor is the core of pressure judgement in an electric pressure cooker; once the diaphragm fatigues, the cooker stops heating or loses pressure control. Diaphragm life verification is still often done by hand: nobody records the force, hold time is by feel, tens of thousands of presses exhaust the operator, and the data cannot be reproduced, leaving type testing and batch sampling without a credible report.
Capability
The machine is a two-station dedicated tester for the life of the central sensor diaphragm fitted to the outer pot of pressure cookers; both stations work independently and can replace manual pressing. The cycle runs automatically: the outer pot with its sensor sits on the positioning bracket, mains and switch wiring are connected, then the stepper motor with reducer drives a linear mechanism down to the set pressure, holds it, lifts, the diaphragm resets, one count is added and the next cycle starts. Test capacity exceeds 20000N. Each station carries its own high-accuracy force sensor over a 0 to 5000N range with a digital display; force is shown and controlled separately per station with settable alarm output, keeping the diaphragm pressing point precise. When pressure reaches the set value the motor reverses and releases automatically. Cycle period and hold time are both 1 to 999s, the rate is 1 to 10 cycles per min, and the counter spans 0 to 999999 shown on the touch screen, with an alarm and stop at the set count. Control is PLC plus touch screen with a two-level password, fault alarm and count-complete alarm are built in, and leakage and under-voltage protection support long unattended runs.


Applicable standards
GB/T 14536.7-2024 Particular requirements for automatic electrical pressure sensing controls (current, effective 2025-05-01, identical to IEC 60730-2-6:2015); GB/T 14536.1-2022 Part 1 General requirements; appliance references GB 13623-2003 aluminium pressure cookers and GB 15066-2004 stainless steel pressure cookers, to be carried over by GB 13623-2026 effective 2027-10-01; test pressure points, cycles and judgement follow the product specification or technical agreement.
Key specifications
- Stations: 2, independent work and independent counting
- Object: central sensor diaphragm mounted on the outer pot
- Drive: stepper motor with reducer plus linear mechanism
- Capacity: maximum test force over 20000N
- Force sensor: 0-5000N per station, digital display, settable alarm output
- Release: motor reverses automatically at set pressure
- Cycle period: 1 to 999s adjustable
- Hold time: 1 to 999s adjustable
- Rate: 1 to 10 cycles per min
- Counter: 0 to 999999, touch screen display, alarm and stop at set count
- Control: PLC plus touch screen, two-level password
- Alarms: fault alarm, count-complete alarm
- Safety: leakage protection, under-voltage protection
Applications
Type and incoming testing of central sensors at electric pressure cooker plants; life sampling at sensor and diaphragm suppliers; endurance verification before a new model is released; pressure sensing control life testing in third-party laboratories
About the manufacturer
Guangdong Endurance Electronic Equipment Co., Ltd provides non-standard customization, drawing confirmation, factory acceptance, on-site installation and commissioning, operation training and long-term technical service; 12-month warranty and long-term spare parts supply. Tel: 0760-88500902 / 13416787649. Web: en.zsnaili.com.