Model: NL-FWF-1
The problem
The pressure limiting valve, safety valve and relief structure are one-shot parts: failing to open is an accident and opening too early is a complaint. Yet factory verification still reads a single gauge peak, six pressure tests need three sets of fixtures, burst pressure needs a separate hydraulic bench, and every cooker model starts the scramble over again.
Capability
The bench covers six pressure tests that GB 13623 and GB 15066 require: working pressure at 0.9 to 1.1 times nominal P, safety pressure at 1.4 to 2.0P, heat resistance at 2.0P held 1min, internal pressure at 3.0P held 30s, relief pressure at 2.0 to 3.5P with gauge pressure within 20kPa sixty seconds after relief, and burst pressure at 6.0P and not below 500kPa. A 2kW electric hot plate heats the cooker; a dedicated hose connector with vent valve links the pressure limiting or safety valve port to a pressure sensor and computer, so the whole pressure-time curve is recorded and the peak is read automatically. Cover closing torque is graded by cooker size: 6Nm for C18 and C20, 9Nm for C22 and C24, 12Nm for C26 and C28, with the pot filled to 50 percent of its volume. Working pressure takes the peak over 30s after continuous venting; safety pressure is observed for 120s from the first safety valve release and the test stops if the upper limit is exceeded. Heat resistance is held at 2.0P for 1min followed by a sealing re-check. Internal and burst pressure are supplied by a hydraulic pump, with 1 to 1.6L/min during the burst stage and the value read when water overflows the rim. A transparent guard keeps relieved parts from flying off, and the run is aborted if pressure reaches the relief limit without venting. One cooker completes the sequence working, safety, heat resistance, relief, internal and burst, with the destructive stage placed last.


Applicable standards
GB 13623-2003 Aluminium pressure cookers, safety and performance requirements; GB 15066-2004 Stainless steel pressure cookers; GB 13623-2026 Safety technical specification for pressure cookers was issued on 2026-09-28 and takes effect on 2027-10-01, replacing both standards, and the bench reserves margin for its pressure and timing values; specific multipliers and judgement follow the product specification or technical agreement.
Key specifications
- Tests: working / safety / heat resistance / internal / relief / burst pressure
- Working pressure: 0.9-1.1P, peak over 30s after valve venting
- Safety pressure: 1.4-2.0P, peak within 120s from first release
- Heat resistance: 2.0P held 1min, then sealing re-check
- Internal pressure: 3.0P held 30s by hydraulic pump
- Relief pressure: 2.0-3.5P, within 20kPa sixty seconds after relief
- Burst pressure: 6.0P and at least 500kPa, water flow 1-1.6L/min
- Heating: 2kW electric hot plate
- Closing torque: 6Nm C18/C20, 9Nm C22/C24, 12Nm C26/C28
- Pressurization: hydraulic test pump for internal and burst stages
- Recording: pressure sensor plus computer curve and peak judgement
- Safety: transparent guard, automatic stop above the upper limit
- Cooker types: aluminium and stainless steel, clamp-lid and twist-lid
- Water fill: 50 percent of cooker volume
Applications
Type testing and batch sampling at pressure cooker manufacturers; safety valve and relief structure verification at cookware and hardware plants; pressure cooker safety testing at inspection bodies; non-reset behaviour confirmation before a new model is released
About the manufacturer
Guangdong Endurance Electronic Equipment Co., Ltd provides non-standard customization, drawing confirmation, factory acceptance, on-site installation and commissioning, operation training and long-term technical service; 12-month warranty and long-term spare parts supply. Tel: 0760-88500902 / 13416787649. Web: en.zsnaili.com.