Model: NL-QY-20N
The problem
Non-metallic enclosures, terminal blocks and switch bobbins pass every room-temperature test, then soften and deform after two years next to a heat source. In safety standards only one test covers this: ball pressure. The apparatus looks simple but is easy to get wrong - a ball that is not vertical, a load off by 0.5N, a scratched support face, or a sample pressed before thermal equilibrium, and the measured impression differs by 0.3mm, leaving the verdict flipping across the pass line.
Capability
The apparatus fixes those variables. Load is 20N plus or minus 0.2N from a deadweight body with a weight set, and the ball and support block are balanced before vertical loading so eccentricity is avoided. The pressing ball is a 5mm diameter bearing steel ball (R2.5) that holds its spherical accuracy in long service. The support block is 50x100mm with a ground, flat and clean face, so a centred sample gets a stable bearing surface. The body is 304 stainless steel, resisting long high-temperature and humid exposure inside a test chamber without corrosion or seizing. A 2.5mm thermocouple hole accepts a probe to read the block and sample interface temperature, so thermal equilibrium is documented rather than estimated. The set includes the deadweight body, weights, sample carrier and ball handling tool, and fits inside standard constant-temperature and drying ovens without wasting chamber space. The procedure follows the standard: apparatus and sample into the oven for 24h or until equilibrium, sample centred on the support, ball lowered gently onto the sample centre, load applied for 1h, ball lifted vertically, then the impression measured within 3min of removal.
Key specifications
- Load: 20N plus or minus 0.2N with weight set
- Pressing ball: 5mm diameter, R2.5, bearing steel
- Support block: 50 x 100mm, ground flat face
- Body material: 304 stainless steel
- Thermocouple hole: 2.5mm
- Structure: deadweight body with weights and balance adjustment, vertical loading
- Accessories: sample carrier, weight set, ball handling tool
- Samples: non-metallic enclosures, terminal blocks, switch bobbins and similar insulating parts
- Test conditions: 24h in oven or thermal equilibrium; 1h load; impression measured within 3min
- Verdict reference: impression diameter 2mm or less per the applicable product standard
Applications
Incoming and type testing of insulating parts at appliance and IT plants; incoming verification by plastic part, terminal block and switch bobbin suppliers; capability set-up at third-party laboratories and safety labs; pre-testing before certification and re-testing after corrective action
About the manufacturer
Guangdong Endurance Electronic Equipment Co., Ltd provides non-standard customization, drawing confirmation, factory acceptance, on-site installation and commissioning, operation training and long-term technical service; 12-month warranty and long-term spare parts supply. Tel: 0760-88500902 / 13416787649. Web: en.zsnaili.com.
Applicable standards
The ball pressure test method follows GB/T 5169.21 (equivalent to IEC 60695-10-2); in product standards it corresponds to GB 4706.1 clause 30.1 (resistance to heat), GB 4943.1, GB 2099.1, IEC 60884, IEC 60335-1, IEC 60598-1, IEC 60730-1 and EN 50548. Test temperature, load duration and impression limits follow the applicable product standard.