Model: NL-KFDCB-2
The problem
The electromagnetic pump is the pressure heart of a coffee machine: short on flow and the extraction rate never arrives; weak on pressure and 9bar becomes a dribble; poor at drawing vacuum and the preheat stage cannot suck water in; add leakage current and safety compliance fails outright. Most lines just power it up and listen - whether flow meets spec and whether the negative pressure works is judged by feel, and by the time a finished machine fails extraction the whole pump batch needs re-inspection.
Capability
The bench runs a four-step program. Step one automatically mates the pump connector and power terminal while monitoring power draw. Step two powers the pump to draw water on a 100-240V variable supply. Step three closes the ball valve and applies pressure with the regulator until the outlet flow reaches the standard value, with test pressure 0-3MPa at 0.01MPa accuracy. Step four releases the inlet side so the pump draws vacuum, judged against the 0.8-1bar gauge band. Flow, pressure, power, voltage and leakage are covered on one machine; each step is timed independently over 0-99.99s; lamps show results and faults stop the pump and release pressure. Two stations run independently, quick-change aluminium fixtures swap for different pump bodies, and the takt is 25-35s per pump, about 200-260 pumps per hour on two stations.

Applicable standards
The assessment follows the structural safety clauses of Chapter 22 and the leakage current clauses of Chapter 16 of GB 4706.1 General requirements for household and similar electrical appliances, with whole-machine safety under GB/T 4706.19-2024; the standard flow value, the 0.8-1bar vacuum band and the test pressure follow the customer technical agreement and the pump specification.
Key specifications
- Stations: 2, independent control
- Test piece: coffee machine electromagnetic (vibration) pump
- Test pressure: 0-3MPa, accuracy 0.01MPa
- Booster pump: 0-3MPa
- Flow check: close ball valve, regulate until outlet flow meets standard
- Vacuum check: release inlet side, gauge band 0.8-1bar
- Monitored: flow / pressure / power / voltage / leakage
- Step time: 0-99.99s settable per step
- Method: water circuit
- Fixture: quick-change aluminium (replaceable)
- Controls: master leakage switch / relief switch / reset switch / start-stop buttons
- Supply input: AC220V 50/60Hz
Applications
Shipment inspection at electromagnetic pump suppliers; incoming inspection and line sampling at coffee machine plants; pump flow-vacuum characteristic validation and re-judgement of returned pumps
About the manufacturer
Guangdong Endurance Electronic Equipment Co., Ltd provides non-standard customization, drawing confirmation, factory acceptance, on-site installation and commissioning, operation training and long-term technical service; 12-month warranty and long-term spare parts supply. Tel: 0760-88500902 / 13416787649. Web: en.zsnaili.com.